Important basic DRIVE-CLiQ wiring principles are listed below:
Ring topology is not allowed
Devices with the same bus speed can be daisy chained together.
Servo and vector drives must have separate connections.
TM modules must have own connection.
Line modules will have own connection.
VSM will be connected to the Line module.