Important basic DRIVE-CLiQ wiring principles are listed below: 

  • Ring topology is not allowed 
  • Devices with the same bus speed can be daisy chained together. 
  • Servo and vector drives must have separate connections. 
  • TM modules must have own connection. 
  • Line modules will have own connection. 
  • VSM will be connected to the Line module. 